<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-22 04-34-09
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 57 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.3 kHz 65 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19000 0,6632
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,8 dBr 4,00 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 4:34, 22.08.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,6632 Acquired: 2026.08.22 4.33.06 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,2 dBr MIN: 1,8 dBr AVE: 4,00 dBr % above 12,2 dBr: 0,0 Last value: 2,0 dBr (2026.08.22 4.33.05) 04.20 04.22 04.24 04.26 04.28 04.30 04.32 0 2 4 6 Pm [dBr]